ASC 25F
Advanced Acoustic Glassbreak Detector  
Unsurpassed microprocessor based technology
analyzes more precise glassbreak frequency domains
Processing time of signal is many times faster
than conventional detectors
Unique Smart-TestTM
installation feature advises optimum mounting location
Installs easily in standard single gang outlet
box
6 year warranty
The ASC Edge:
The ASC25F Series takes a significant lead over other leading brands of glassbreak
detectors in these three vital ways:
A Smarter Microprocessor for Better Performance:
As the result of extensive R&D efforts... The ASC25F is able to focus on significantly
more precise frequency domains. The discovery of a top end frequency range, substantially
higher than previous technology believed to exist during a glassbreak event has proven to
be a key component of the advanced algorithms developed for the ASC25F microprocessor.
This means unsurpassed detection in even the most difficult, acoustically "soft"
environments.
Faster Processing Eliminates False Alarms:
The ASC25F utilizes the fastest signal processing of any glassbreak available. In fact,
the collection of sound data is analyzed five times faster than the leading
detectors sold today.
The ASC25F operates knowing that the actual glassbreak event itself occurs in a
fraction of the time previously thought. All other associated sound such as glass
shattering on the floor or hitting other objects is superfluous to the actual processing.
Reverberant sounds (which nearly all false alarm signals contain); are ignored. You have
the assurance that the ASC25F will detect broken glass associated with intrusion; and set
a new standard in false alarm freedom.
Smart-TestTM Means Faster, Easier Installations:
In addition to verifying range, Smart-TestTM provides two-way
feedback, warning you of potential environmental trouble. It will actually tell you if the
detector is placed correctly or should be moved to another location. It indicates low or
high end frequency disturbances by flashing the LED at specific rates. This built-in test
features makes the ASC25F the fastest and easiest to install.
ASC 25F Specifications:
| Coverage |
25' (7.6m) maximum to farthest point of glass being protected. For glass sizes over
12" x 12"
(0.3m x 0.3m), types of 1/4" (0.64cm) plate, tempered, laminated and wired glass,
and 1/8" (0.32cm) plate glass (DSB) |
| Mounting |
Directly to the ceiling, on an opposite wall, or an adjacent wall |
| Input Power |
12 VDC (9 VDC min. to 15 VDC max.) 21 mA nominal @ 12 VDC (24 mA max. in LED latch
mode) |
| Standby |
Connect to power sources capable of supplying standby power of 23 mA-H for each hour
of required standby time. 4-hour minimum standby time required for U.L. Certificated
installations |
| Relay |
Normally closed reed relay (NC/C). Contacts rated 3.5 watts, 125 mA @ 28 VDC for DC
resistive loads. Protected by 4.7 ohm resistor in common "C" leg |
| Temperature |
-20 to +120ºF (-29 to +49ºC) +32 to +120ºF (0º to +49ºC) for U.L. Certificated
installation |
| Dimensions |
ASC25F: 4.8" H x 3.25" W x 0.5 "D (122mm H x 83mm W x 13mm D)
(0.25" D installed) |
| Accessories |
ASC-GBS Glass Break Simulator for Testing |
How to Order:
ASC25F--Advanced acoustic glassbreak detector in flush mount case
ASC-GBS--Glassbreak simulator for installation and testing
Applications
Maximum detection range is 25' (7.6m) from
the farthest corner of the protected glass
Detector requires a clear unobstructed view of
the entire glass surface being protected
Set-Up and Testing
Activate Smart-TestTM mode
by applying magnet (in top case of ASC-GBS simulator) to test point on detector case
Alarm LED will flash for 10 seconds
Detector will remain in Test Mode for 5 minutes
and automatically time out
Testing is done with case cover in place
Accessories:
ASC-GBS  |